DSpace Repository

All solid state chromium(III) selective potentiometric sensor based on 2-(1-(2-((3-(2-Hydroxyphenyl)-1Hpyrozol-1-yl) Methyl) Benzyl)-1H-Pyrazol-3-yl) phenol

Show simple item record

dc.contributor.author Kumar, Pankaj
dc.contributor.author Kumar, Sanjeev
dc.contributor.author Jain, Sapna
dc.contributor.author Lamba, Bhawna Y.
dc.contributor.author Joshi, Girdhar
dc.contributor.author Arora, Shefali
dc.date.accessioned 2015-03-13T07:26:16Z
dc.date.available 2015-03-13T07:26:16Z
dc.date.issued 2014
dc.identifier.citation Electroanalysis, 26, 1 – 8. en_US
dc.identifier.other DOI: 10.1002/elan.201400163
dc.identifier.uri http://hdl.handle.net/123456789/1893
dc.description.abstract Highly selective all solid state electrochemical sensor based on a synthesized compound i.e. 2-(1-(2-((3- (2-hydroxyphenyl)-1H-pyrozol-1-yl)methyl)benzyl)-1Hpyrazol- 3-yl)phenol (I) as an ionophore has been prepared and investigated for the selective quantification of chromium(III) ions. The effect of various plasticizers, viz. dibutyl phosphonate (DBP), dibutyl(butyl) phosphonate (DBBP), nitrophenyl octyl ether (NPOE), tris-(2-ethylhexyl) phosphonate (TEP), tri-butyl phosphonate (TBP), dioctyl phthalate (DOP), dioctyl sebacate (DOS), benzyl acetate (BA) and acetophenone (AP) along with anion excluders NaTPB (sodium tetraphenyl borate) and KClTPB (potassium(tetrakis-4-chlorophenyl)borate was also studied. The optimum composition of the best performing membrane contained (I):KClTPB:NPOE:PVC in the ratio 15 : 3 :40 :42 w/w. The sensor exhibited near Nernstian slope of 20.1 0.2 mV/decade of activity in the working concentration range of 1.2 10 7–1.0 10 1 M, and in a pH range of 3.8–4.5. The sensor exhibited a fast response time of 10 s and could be used for about 5 months without any considerable divergence in potentials. The proposed sensor showed very good selectivity over most of the common cations including Na+, Li+, K+ , Cu2+, Sr2+, Ni2+, Co2+, Ba2+, Hg2+, Pb2+, Zn2+, Cs+, Mg2+, Cd2+, Al3+, Fe3+and La3+. The activity of Cr(III) ions was successfully determined in the industrial waste samples by using this sensor. en_US
dc.subject Chromium en_US
dc.title All solid state chromium(III) selective potentiometric sensor based on 2-(1-(2-((3-(2-Hydroxyphenyl)-1Hpyrozol-1-yl) Methyl) Benzyl)-1H-Pyrazol-3-yl) phenol en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account